Flash & Fire Point Apparatus
Flash & Fire Point Apparatus

Flash & Fire Point Apparatus

MOQ : 1 Unit

Flash & Fire Point Apparatus Specification

  • Mounting Type
  • Table Top
  • Humidity
  • Up to 85% RH
  • Gas Pressure
  • Ambient
  • Max Height
  • Approx. 350 mm
  • Test Range
  • Room Temperature to 350C
  • Response Time
  • Immediate (on ignition)
  • Accuracy
  • 1C
  • Resolution
  • 0.1C
  • Operating Voltage
  • 230 V AC
  • Power Supply
  • 230 V AC, 50 Hz
  • Number of Specimens
  • Single Specimen/Test
  • Equipment Type
  • Flash & Fire Point Apparatus
  • Temperature
  • Ambient to 400C
  • Features
  • Flame exposure mechanism, Removable cup, Standardized test procedure
  • Automation Grade
  • Manual
  • Frequency
  • 50 Hz
  • Measuring Range
  • Ambient to 350C
  • Port Size
  • Standard Cup Size
  • Interface Type
  • Manual operation, no digital interface
  • Specimen Size
  • Cup Capacity: 70 ml approx.
  • Usage
  • Lab testing of flash & fire points
  • Capacity
  • 70 ml (Test Cup)
  • Machine Weight
  • 8 kg
  • Control Mode
  • Manual
 

Flash & Fire Point Apparatus Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Supply Ability
  • Unit
  • Delivery Time
  • 1 Months
  • Packaging Details
  • Paid Packaging
  • Main Domestic Market
  • All India
 

About Flash & Fire Point Apparatus

Having a sound record of success, we have attained great heights as a manufacturer, supplier and exporter of Flash & Fire Point Apparatus. It is used to determine the sensitivity of different materials for fire that are used in shipping and safety regulations. Being integrated with latest features, it allows to test both liquid and highly viscous material without the need of adding any extra equipment. We take care that Flash & Fire Point Apparatus is duly checked to ensure its flawlessness.

Features:

  • Accurate results
  • Compact size
  • Lightweight
  • Longer service life

Additional information:

Fully Automatic Flash & Fire point Apparatus:
Determination of the Flash- and Fire-Point with Open Cup - Cleveland Method  (automatic)
AS PER IS 1209: 1978

This flash point and fire-point test method is a dynamic method and depends on definite rates of temperature increases to control the precision of the method.

Its primary use is for viscous materials having a flash point between 79 except fuel oils, to define the hazards of flammable and combustible materials used in shipping and safety regulations.

The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.

The flash point is the lowest liquid temperature at which application of the flame causes the vapors of the test specimen of the sample to ignite. To determine the fire-point, the test is continued until the application of the test flame causes the test specimen to ignite and sustain burning for a minimum of 5s.


It is an automatic flash and fire-point tester used to examine liquid as well as highly viscous samples in the same instrument without any additional equipment.

For substances with unknown flash points, the APPARATUS has a special search mode program. During the entire heating period, the test flame is moved across the sample at suitable intervals. The expected flash point of a specimen can thereby be found in a time saving and economical manner.

Optional On demand:

When examining highly viscous specimens, a preheating time and temperature are set in order to warm-up and liquefy the sample to inserted temperature probe without problem. Further a skimmer is removing the surface skin from bituminous samples.

Standard Cup with handle, made of brass

Temperature Probe Pt-100 for sample temperature

Electric Gas Igniter with connector cable and plugs

Flame Detection Unit for the detection of flash- and fire-points Flame Arrest Cover for extinguishing the fire in the cup

Specification:

Fully Automatic Flash and Fire point apparatus (by cleaveland open cup method).

  • Temp.Range: Ambient to 400C with RTD sensor.

  • Flame-Detector: Ionization principle based flame-detector sensor.

  • Stirrer: 60 Rpm, A.C. 230 v, 50 Hz. Synchronous motor.

  • Controller: Microprocessor based process controller cum indicator with 3-wire RTD temperature sensor, free potential flame detector sensor as i/p and 230 v triac as relay o/p.

  • Lid-Closing Motor: 60 Rpm, A.C. 230 v, 50 Hz, synchronous motor for de-combustion.

  • Assembly up/down: Motorized 12 v D.C. jack for ease-of-use.

  • Flame-Sampling Arrangement: 10 Rpm, D.C. 12 v, gear motor, vertical movement reciprocating motion.

  • Heater: 800 W, 230 v.

  • Electrical ignition for flame-sampling. Ignition transformer having continuous o/p of 10.6 Kv. D.C. from 230 v A.C. i/p.

  • Equipment Overall Size 

  • Equipment Gross Weight: 21 Kg.

  • Supply: 230 v, 50 Hz supply with proper earthing system.

 



Precision Measurement and Safety

This apparatus guarantees accurate temperature control with 1C accuracy and a fast response time upon ignition. The integrated overtemperature protection and insulated handle prioritize user safety during flash and fire point testing. Its robust construction ensures long-term, reliable operation even under demanding laboratory conditions.


User-Friendly Manual Operation

Designed with simplicity, the Flash & Fire Point Apparatus employs a manual control mode with straightforward stirring and flame application. The removable test cup permits quick specimen changes, while the included user manual provides step-by-step guidance for repeatable, standardized test procedures.


Comprehensive Accessory Kit

Each apparatus comes complete with all essential accessories, including the test cup (70 ml), thermometer, heater, flame applicator, and clear user manual. This comprehensive kit streamlines setup and helps ensure every test is conducted in compliance with recognized standards.

FAQs of Flash & Fire Point Apparatus:


Q: How is the Flash & Fire Point Apparatus operated during tests?

A: Operation involves placing a specimen in the chrome-plated cup and using the manual stirrer and electric heater to gradually raise the temperature. The gas jet and flame applicator are utilized to detect flash or fire points, following the standardized Cleveland Open Cup method.

Q: What substances can be tested using this apparatus?

A: This equipment is specifically designed for laboratory testing of petroleum products and other flammable liquids, according to IS 1448 (P:69) and ASTM D92 protocols within a temperature range from room temperature up to 350C.

Q: When should I use the overtemperature protection feature?

A: Overtemperature protection is automatically active, safeguarding both operator and specimen by preventing excessive temperature rise, thus ensuring lab safety during the testing process.

Q: Where can this apparatus be installed for optimal use?

A: The device is intended for laboratory use and is easily placed on a sturdy tabletop. Its compact design and standard power requirements (230 V AC, 50 Hz) allow convenient installation in most laboratory settings.

Q: What is the benefit of using a manual operation interface?

A: Manual control grants users immediate oversight throughout the flash and fire point testing process, resulting in high precision and compliance with standardized test methods. This also reduces potential software or calibration errors.

Q: How accurate are the flash and fire point readings?

A: Readings are exceptionally precise, with a measurement accuracy of 1C and a resolution of 0.1C, ensuring dependable results for research, quality assurance, or industrial applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in IS/ASTM Test/Measuring Instruments Category

Digital Penetrometer

Digital Penetrometer

Minimum Order Quantity : 1 Unit

Capacity : 200g

Specimen Size : Standard Dimensions

Power Supply : AC 220V, 50 Hz

Equipment Type : Digital Penetrometer

Number of Specimens : 1

Louvandro Meter

Louvandro Meter

Minimum Order Quantity : 1 Unit

Capacity : 5 N, 10 N, 20 N

Specimen Size : 100 mm x 100 mm

Power Supply : 220 V AC, 50 Hz

Equipment Type : Louvandro Meter

Number of Specimens : 1

Ductility Apparatus

Ductility Apparatus

Minimum Order Quantity : 1 Unit

Capacity : Up to 3 samples per test

Specimen Size : 10 mm x 6 mm x 50 mm

Power Supply : 230 V AC, 50 Hz

Equipment Type : Ductility Measuring Apparatus

Number of Specimens : 3 specimen slots

Salt Spray Chamber

Salt Spray Chamber

Minimum Order Quantity : 1 Unit

Capacity : 108 liters

Specimen Size : Up to 150 70 mm

Power Supply : 220V AC / 50Hz

Equipment Type : Corrosion Testing Chamber

Number of Specimens : Up to 40 pieces