Having a sound record of success, we have attained great heights as a manufacturer, supplier and exporter of Flash & Fire Point Apparatus. It is used to determine the sensitivity of different materials for fire that are used in shipping and safety regulations. Being integrated with latest features, it allows to test both liquid and highly viscous material without the need of adding any extra equipment. We take care that Flash & Fire Point Apparatus is duly checked to ensure its flawlessness.
Features:
Additional information:
Fully Automatic Flash & Fire point Apparatus:
Determination of the Flash- and Fire-Point with Open Cup - Cleveland Method (automatic)
AS PER IS 1209: 1978
This flash point and fire-point test method is a dynamic method and depends on definite rates of temperature increases to control the precision of the method.
Its primary use is for viscous materials having a flash point between 79 except fuel oils, to define the hazards of flammable and combustible materials used in shipping and safety regulations.
The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.
The flash point is the lowest liquid temperature at which application of the flame causes the vapors of the test specimen of the sample to ignite. | To determine the fire-point, the test is continued until the application of the test flame causes the test specimen to ignite and sustain burning for a minimum of 5s. |
It is an automatic flash and fire-point tester used to examine liquid as well as highly viscous samples in the same instrument without any additional equipment.
For substances with unknown flash points, the APPARATUS has a special search mode program. During the entire heating period, the test flame is moved across the sample at suitable intervals. The expected flash point of a specimen can thereby be found in a time saving and economical manner.
Optional On demand:
When examining highly viscous specimens, a preheating time and temperature are set in order to warm-up and liquefy the sample to inserted temperature probe without problem. Further a skimmer is removing the surface skin from bituminous samples.
Standard Cup with handle, made of brass
Temperature Probe Pt-100 for sample temperature
Electric Gas Igniter with connector cable and plugs
Flame Detection Unit for the detection of flash- and fire-points Flame Arrest Cover for extinguishing the fire in the cup
Specification:
Fully Automatic Flash and Fire point apparatus (by cleaveland open cup method).
Temp.Range: Ambient to 400C with RTD sensor.
Flame-Detector: Ionization principle based flame-detector sensor.
Stirrer: 60 Rpm, A.C. 230 v, 50 Hz. Synchronous motor.
Controller: Microprocessor based process controller cum indicator with 3-wire RTD temperature sensor, free potential flame detector sensor as i/p and 230 v triac as relay o/p.
Lid-Closing Motor: 60 Rpm, A.C. 230 v, 50 Hz, synchronous motor for de-combustion.
Assembly up/down: Motorized 12 v D.C. jack for ease-of-use.
Flame-Sampling Arrangement: 10 Rpm, D.C. 12 v, gear motor, vertical movement reciprocating motion.
Heater: 800 W, 230 v.
Electrical ignition for flame-sampling. Ignition transformer having continuous o/p of 10.6 Kv. D.C. from 230 v A.C. i/p.
Equipment Overall Size
Equipment Gross Weight: 21 Kg.
Supply: 230 v, 50 Hz supply with proper earthing system.